Read this page before you wire anything into a spa, and again before you enable transmit.

Electrical safety

Mains voltage and water

A spa controller runs on mains voltage and can deliver a large fault current. Water makes a shock more likely and more severe.

  • Isolate the spa before you open it. Switch off the spa's breaker or isolator at the supply, not only at the topside. The topside does not disconnect mains from the board.
  • Check that it is dead. Use a suitable voltage tester before you touch anything in the control box.
  • Use only the RS485 header. The header on the control board is intended for a second topside panel. Do not take power or signals from any other point on the board.
  • Keep low-voltage parts dry and fixed. Mount the adapter or ESP32 in an enclosure, away from water and away from mains terminals. Route the bus cable so that it cannot touch mains parts.
  • Follow local rules. In many countries, work inside fixed mains equipment needs a qualified electrician. If you are not sure, ask one.
  • Your risk. Wiring anything into a spa is at your own risk. This project gives no warranty.

Receive-only by default

Both the MQTT bridge and the ESPHome component start with transmit off. With transmit off:

  • Nothing is ever written to the bus. The bridge, the monitor and the capture tool only listen.
  • Buttons and the temperature setpoint still appear in Home Assistant, so their identities stay the same. The MQTT bridge shows them as unavailable. ESPHome logs a warning when you press one.
  • A wrong setting or a wrong tub definition can show wrong values. It cannot change the tub.

You enable transmit on purpose, with SPA_TRANSMIT=true or spa.transmit: true for the bridge, or transmit: true in the ESPHome spa_bus: block.

The read-only tools never transmit, whatever the setting:

  • spa2mqtt monitor runs receive-only and wraps its connection so that any write fails.
  • spa2mqtt replay reads a file and has no bus at all.
  • tools/capture.py contains no send call.

One choke point for every write

Every write to the bus goes through one function:

  • Python: BusWriter.send() in spa2mqtt/tub/bus.py.
  • ESPHome: SpaBus::transmit_frame_() in esphome/components/spa_bus/spa_bus.cpp.

Each is marked TRANSMITS in the source. A test asserts that no other Python module writes to the transport. If transmit is off, the Python writer raises an error and the C++ function returns before it writes. One choke point makes the transmit path easy to review: you check one function, not the whole code base.

What enabling transmit does

When you enable transmit:

  1. At start-up, nothing changes on the bus. The bridge logs TRANSMIT ENABLED, and the command entities become available in Home Assistant.
  2. On the first command from Home Assistant, the bridge claims a client channel on the bus. It does this the same way a second topside panel does: it takes a polled channel that no device uses, or it asks the board for a new channel and acknowledges the answer. From then on, the board polls that channel.
  3. When the board polls the channel, the bridge sends one queued button press. When nothing is queued, it stays silent.
  4. A setpoint change is a series of single up or down presses. After each press the bridge waits for status frames that confirm the change, and it gives up after a fixed number of attempts.
  5. If another device answers on the same channel, the bridge sees the conflict and goes back to listening.

The v1 bridge claimed a channel at start-up even when no one pressed a button. Version 2 does not.

The transmit path is tested against a simulated board, and runs on the project's own J235 through the MQTT bridge: the board granted channel 0x11 (protocol.md, D8). Watch the first commands at the topside of your own tub.

The J345 definition uses bus.mode: direct. The ProLink's TCP stream carries no polls, so there is no channel to claim. When you enable transmit:

  1. At start-up and on every reconnect, nothing is sent.
  2. On the first command after each connection, the bridge sends one connection-check frame (type 0x19). pyjacuzzi sends the same frame first. Whether the tub needs it is unknown.
  3. Each command is one frame, sent from the ProLink's own bus address (0x0A). Frames are at least four status frames apart, about 1.2 seconds.
  4. A setpoint change is a single set-temperature frame with the target in whole °F. The bridge refuses a target outside 80–104 °F. It does not clamp it. The setpoint is also blocked while the tub reports Celsius mode, and until the first status frame is decoded: in Celsius mode the same byte would mean half degrees Celsius.
  5. Nothing is retried. At most eight commands wait in the queue, and a reconnect drops them.

Every frame this mode can send is a frame that pyjacuzzi sent to the owner's tub in a captured session, reproduced byte for byte, with one exception: setpoints other than 90, 100 and 101 °F use the same frame with another value. A test enumerates every frame the definition can emit and fails if any other appears. The project has not run this path against the tub. See the J345 guide for the order of first tests.

Rules for testing

  • Never leave transmit on while you test an unknown or changed tub definition. A wrong button code, bus address or channel setting could send a command that you did not intend, or disturb the topside panel's own traffic. Test with transmit off until every value matches the topside.
  • Test new definitions with spa2mqtt monitor and replayed captures first. See Monitor and capture.
  • Enable transmit when someone can watch the topside. Press one button at a time and check the result.
  • If anything unexpected happens, set transmit off again and restart. If the topside shows an error, isolate the spa at the breaker and wait before you switch it on again.
  • Do not automate heating or pumps from Home Assistant until manual commands have worked reliably for some time.